The third assignment for AD Converters (ADC) was about combining noise sources into SNDR and ENOB, and about oversampling. Corrections to the exercises will be processed and marked in red.
Q1
A 500 MHz signal with 50 mV peak-peak amplitude must be converted by an N-bit ADC. The sample clock shows a jitter of 1 ps rms, sampling on a 2 pF sample capacitor. The second order harmonic distortion of the signal is at -60 dB. An ENOB = 7 bit is required.
A
Calculate N, round up to integer.
To calculate the amount of bits this ADC should use for a ENOB of 7, we can use the formula given for ENOB at page 439 of Marcel Pelgrom’s A/D Converters book.
We find SNDR here by finding the ratio between the signal power and sum of the power of all other noise elements. First, we can solve for the needed SNDR since ENOB is known.
This gives us SNDR
- The signal has a 50 mV peak to peak, giving a peak value of 25 mV. The RMS of the signal thus is
- To find the
, we must find the noise of all (known) noise and sum these up.- The
is - The
is given as 60 dB - The
is given with
- The
Now we will add these using the following formula from page 439 of A/D Converters (note that we don’t use the dB values, I calculated the intermediate dB values for sake of completeness):
We need to solve for the SNQR, since this equation is dependent on the amount of bits used;
We get the following
The denominator is the
Now
Now we can solve for N;
B
The signal amplitude is now increased. All values (jitter, sample cap, distortion) remain the same and use N = 8. At what amplitude is ENOB = 7.4 bit reached?
From Eq. 1 we can derive the required SNR;
Now that we have the required SNDR, we can use Eq. 2 and redefine our
Now since SNDR is equal to
thus,
I left out some steps since Q1 was getting quite long.
Q2
The output signal of an FM intermediate frequency circuit has a bandwidth of 100 kHz at a carrier frequency of 10.7 MHz. An analog-to-digital converter samples this signal at 5.35 Ms/s. What resolution is needed to obtain a SNQR due to quantization of 13.8 bit in 100 kHz bandwidth?
With 13.8 we can calculate the required SNQR;
Page 862 of the book talks about oversampling. The oversampling ratio OSR is given by
It further states that the quantization error spectrum is modeled as white noise, uniformly distributed over the band from 0 to
Thus, the noise is spread evenly across a larger BW (0 to 2.675 MHz), meaning that the noise power inside our signal BW (0 to 100 kHz) is smaller. Also on page 862, we get the following equation:
Now we can solve for N to find the resolution needed
Q3
An ideal 10 bit ADC is sampling at 50 Ms/s a full-scale 12 MHz input signal with 2nd harmonic. The second harmonic is expected worst case to be around 54 dB level.
A
What is the expected SNDR?
From the given information, we only have quantization error and harmonic distortion. Thus the SNDR can be defined as
Then divide by
This is now the inverse of the SNR’s, so we can substitute the terms in the denominator by
Using the SQNR equation with N = 10 we find that the SNQR is 61.96 dB, which linearly is
We combine these to get a total SNDR using Eq. 5 to get
B
The measurement shows an SNDR of 56 dB. At what level is the 2nd harmonic?
The actual SNDR is given to be 56 dB, and we have to find the harmonic. Our SNDR has improved, and we assume that the SNQR remained the same (makes sense if the amount of bits has not changed). The SNDR in linear terms is
Rearranging Eq. 5 now to find the SNR
which gives
Thus, we have
C
In order to measure the 2nd harmonic exactly, a filter around
To limit the SNQR to -90 dB, we need to find an improvement of 28.04 dB. We can use the OSR here, and solve for the BW.
Using here
D
There are only low-pass filters (from DC to BW) available. How can you measure the 12 MHz signal and its harmonic?
If only lowpass filters are available, aliasing can be used. This will allow us to separate the fundamental and second harmonic in the first Nyquist zone, so a low pass filter can be used.
Q4
A 10-bit ADC samples at 200 Ms/s an input signal of 500 mVpp in a band between 80-90 MHz. The input uses a 3 pF capacitor and the jitter on the sampling signal is 1 ps rms.
A
What is the effective resolution (ENOB) in the 10 MHz band between 80 MHz and 90 MHz?
To find the ENOB we return to Eq. 1. To find the SNDR for the ENOB we return to Eq. 5, this time adding thermal and jitter noise as well. Some calculations will be left out and only the result will be shown to avoid repetition and unnecessary detail.
From given;
= 0.03125 V- SQNR = 61.96 dB =
- SNR
= 73.5 dB = - SNR
(at 90 MHz) = 65 dB =
Thus the SNDR using Eq. 5 is 59.8 dB. This gives us
B
The succeeding digital electronics uses only every second sample and discards the intermediate samples, thereby halving the sample rate. What will happen to the signal and what is the ENOB in the resulting 10 MHz bandwidth?
If we only use every second sample, then our sample rate will be 100 MHz. This means the Nyquist zone reduces to 0 to 50 MHz. Since our signal sits between 80 to 90 MHz, aliasing has to be used. Using
We expect the ENOB to go down since a lower
C
Is it a good idea to reduce the sample rate of the ADC to 100 Ms/s?
D
Is there a better solution resulting in a higher ENOB?
A good alternative way is to use digital processing, then we can keep the same quality of our analog processing and throw away not needed samples digitally.